Agilent 4339B High Resistance Meters

Agilent 4339B High Resistance Meters

 

 

For precision bench-top applications, the 1-channel 4339B is the premier solution for accurate high resistance and low current tests. For high resistance testing in manufacturing environments, the 4349B offers simultaneous 4-channel high resistance measurements for increased test throughput.

High quality results
• High confidence testing with
contact check function
• Remove parasitics with error
correction
• Consistent data with 0.6% basic
accuracy
• Compensation for handler contact
chattering with trigger delay
Versatile measurements
• Select from four test parameters
• Use a variety of test fixtures
and accessories
• Perform a charge-measuredischarge sequence with the test
sequence program function
• Save and recall up to ten
measurement setups
High test throughput
• 9.5 ms measurements
• 4-channels for multiple DUTs
• 4-channel simultaneous testing
• Fast contact checking: 2 ms/
measurement
• GPIB and handler interfaces
• Ideal for high volume capacitor
testing

Key parameters and specifications

Test channels                                                                       1
Test voltage(Vdc)                                                      0.1 to 1000
Measurement parameters                                        R, I, pv, ps
Measurement range (Ω)                                   10^3 to 1.6×10^16
Basic accuracy                                                                 0.6%
Display resolution                                                3 / 4 / 5 digits
Measurement time                                         10 ms/30 ms/390 ms

High quality measurements
with flexible hardware
• Resolve data to 5 digits
(3, 4, or 5 digits selectable)
• Make precise measurements
with 0.6% basic accuracy
• Verify DUT performance at
the exact voltage rating
• Reliable and safety measurements
with Agilent 16339A component
test fixture

4339B solutions for high
voltage material testing
• Resistivity mathematics built-in:
surface and volume
• Agilent 16008B resistivity cell for
solid samples
• Easy measurements with test
sequence program function
(controls charge-measuredischarge sequence)
• Customize your fixture cabling
with the Agilent 16117C test

System features you need to
be successful
• Maximize accuracy with
error correction
• Test capacitor contact failure
with contact check function
• Automate testing with GPIB
interface
• Reduce ground-loops with
isolated handler interface
• Pass/Fail testing with comparator
function (high/in/low)