{"id":232,"date":"2021-04-30T13:20:35","date_gmt":"2021-04-30T10:20:35","guid":{"rendered":"https:\/\/labsensors.org\/?page_id=232"},"modified":"2021-05-17T12:01:44","modified_gmt":"2021-05-17T09:01:44","slug":"fsm-1202","status":"publish","type":"page","link":"https:\/\/labsensors.org\/en\/equipment\/fsm-1202\/","title":{"rendered":"Universal laboratory IR Fourier spectrometer FSM 1202"},"content":{"rendered":"<h1><\/h1>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-233\" src=\"https:\/\/labsensors.org\/wp-content\/uploads\/2021\/04\/fsm1202.jpg\" alt=\"\" width=\"300\" height=\"259\" \/><\/p>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"ru\" data-phrase-index=\"0\">The FSM 1202 universal laboratory IR Fourier spectrometer is designed for routine measurements and scientific research in the mid-infrared region of the spectrum.<\/span><\/span><\/p>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"ru\" data-phrase-index=\"0\">The spectrometer is used for quantitative analysis and quality control of products in the chemical, petrochemical, fuel, pharmaceutical, food and perfume industries, for environmental control, forensic and other types of expertise.<\/span><\/span><\/p>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"ru\" data-phrase-index=\"0\">The FSM 1202 spectrometer is based on a Michelson-type interferometer with self-compensation, which does not require dynamic alignment.<\/span><\/span><\/p>\n<p><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"ru\" data-phrase-index=\"0\">FT-IR spectrometer model FSM 1202 was produced by OOO Monitoring and OOO Infrapec (St. Petersburg) in the period from 1999 to 2016.<\/span><\/span><\/p>\n<p>&nbsp;<\/p>\n<div class=\"ccvoYb\">\n<div class=\"AxqVh\">\n<div class=\"OPPzxe\">\n<div class=\"dePhmb\">\n<div id=\"ow1474\" class=\"eyKpYb\" data-language=\"en\" data-original-language=\"ru\" data-result-index=\"0\">\n<div class=\"J0lOec\">\n<p><strong><span class=\"VIiyi\" lang=\"en\"><span class=\"JLqJ4b ChMk0b\" data-language-for-alternatives=\"en\" data-language-to-translate-into=\"ru\" data-phrase-index=\"0\">Specifications<\/span><\/span><\/strong><\/p>\n<div class=\"l6VmFb\">\n<div id=\"ow1478\" data-append-to-body=\"true\" data-propagate-tooltip-mouseover-events=\"false\" data-anchor-corner=\"bottom-center\" data-popup-corner=\"top-center\">\n<div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"kGmWO\"><\/div>\n<table width=\"600\">\n<tbody>\n<tr>\n<td width=\"400\">\n<p style=\"text-align: center;\">Spectral range, cm^-1<\/p>\n<\/td>\n<td style=\"text-align: center;\">400-7800<\/td>\n<\/tr>\n<tr>\n<td width=\"400\">\n<p style=\"text-align: center;\">Spectral resolution, cm^-1<\/p>\n<\/td>\n<td style=\"text-align: center;\">0,5<\/td>\n<\/tr>\n<tr>\n<td width=\"400\">\n<p style=\"text-align: center;\">Signal-to-noise ratio (measurement time 1 min in the interval 2100-2200 cm^-1 and resolution 4 cm^-1)<\/p>\n<\/td>\n<td style=\"text-align: center;\">> 20 000<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"400\">The minimum time to obtain one full spectrum is less, s<\/td>\n<td>\n<p style=\"text-align: center;\">1<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"400\">Beam splitter<\/td>\n<td>\n<p style=\"text-align: center;\">Ge-coated KBr<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"400\">\n<p style=\"text-align: center;\">Radiation source<\/p>\n<\/td>\n<td>\n<p style=\"text-align: center;\">High temperature cermet<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center;\" width=\"400\">Detector<\/td>\n<td>\n<p style=\"text-align: center;\">Pyroreceiver LiTaO<sub>3<\/sub><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>The FSM 1202 universal laboratory IR Fourier spectrometer is designed for routine measurements and scientific research in the mid-infrared region of the spectrum. The spectrometer is used for quantitative analysis and quality control of products in the chemical, petrochemical, fuel, pharmaceutical, food and perfume industries, for environmental control, forensic and other types of expertise. The [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":18,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-232","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/labsensors.org\/en\/wp-json\/wp\/v2\/pages\/232","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/labsensors.org\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/labsensors.org\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/labsensors.org\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/labsensors.org\/en\/wp-json\/wp\/v2\/comments?post=232"}],"version-history":[{"count":2,"href":"https:\/\/labsensors.org\/en\/wp-json\/wp\/v2\/pages\/232\/revisions"}],"predecessor-version":[{"id":365,"href":"https:\/\/labsensors.org\/en\/wp-json\/wp\/v2\/pages\/232\/revisions\/365"}],"up":[{"embeddable":true,"href":"https:\/\/labsensors.org\/en\/wp-json\/wp\/v2\/pages\/18"}],"wp:attachment":[{"href":"https:\/\/labsensors.org\/en\/wp-json\/wp\/v2\/media?parent=232"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}